BeamOn HR-Laser Beam Analysis
$15.14
$19.68
The BeamOn HR system is a beam diagnostics measurement system for real-time measurement of CW or Pulsed laser beams. It provides laser beam parameters, such as: beam width, shape, position, power, and intensity profiles. Software also provides report function for beam analysis settings and results (see an example on Downloads). The BeamOn HR is based on a USB 2.0 CCD Camera, software driven device, which can be connected to a Notebook (or Desktop) computer via the High Speed USB 2.0 port and run on Windows 7 / 8 / 10 OS (32 & 64 bit). *New feature: Built-in motorized filter wheel controlled by software (or ActiveX) further widening the optical bandwidth. Specifications Parameters Value Camera type Monochrome interline transfer progressive scan,1.4MP CCD 1/2″format Sensor active area 6.47mm×4.83mm Pixel size 4.65um×4.65um Max frame rate 15fps at 1392×1040,30fps with binning(2×) Image resolution 1392×1040 Spectral response 350~1310nm Weight 165 gr Power consumption 6V,4Watts Accessories included Filter wheel with 3×NG Schott colored filters (NG4,NG9,NG10) in housing.Adaptor ring for user filter.Mounting post Mounting consumption 3/4″×32 when filter wheel removed Shutter speed 0.6sec to 1usec Gain Control ×1 to ×23 Dynamic range 60dB not include filters Sensitivity 5nW/cm2@633nm,60uW/mm2@1310nm Saturation intensity 2mW/cm2 Damage threshold 50W/cm2 with filters Operation with pulse lasers: Abillty to capture and replay image from slowly pulsing laser(1~100Hz)while filtering out frames with no laser pulse.Gain control and external filter make it easy to abtain optimal intensity Trigger in RCA female jack,4.5V squre wave TTL Hardware triggering: In pulse mode set threshold by slide bar to display frames with captured pulse BeamOn IR-1550nm spec: Spectral response 1550nm±50nm Sensitivity 22uW/mm2 Saturation 10mW/mm2 Ordering Information BeamOn HR: A camera for 350 – 1310nm, a standard USB2.0 cable, a post, a set of 3XND filters in housing on a built-in filter wheel (removable), software on CD disk, carrying case. BeamOn HR 1550: A camera for 1550nm /-50nm BeamOn HR-AFW: Built in Motorized automatic filter wheel. Additional accessories SAM1 Beam sampler (ratio 3X10^(-3)) SAM2 Beam sampler (ratio 1X10^(-6)) SAM3-A: Beam sampler polarization preserving (ratio 0.0016 Avg) RDC Beam reducer (ratio 2X1) RDC-FILT: 1/8 ND filter, M37X0.75 MOUNTB: Mounting base NG-Filters: 1.6mm thick Schott colored filter in housing with adaptor, types: NG4/NG9/NG10 Adapter: C-Mount adapter ring
Light Spot Analyzers