Beam Analyzer Touch-Laser Beam Analysis
$33.53
$57.67
New small footprint and powerful stand alone unit with built-in touch screen and measuring head. Patented technology (unique tomographic image reconstruction of 2D/3D images), measure beam profile, beam size, beam shape, position and power. Wide spectral range from 190nm through 2700nm, beam sizes from 2um to 10mm with 0.1um resolution. Including: industrial unit with LCD 7 inch wide touch screen, resolution 800X400 contrast ratio 350:1, Windows 7 pro, 4xRS-232, 2xLAN PORT. Specifications Sensor type Silicone(Si) UV-Silicon (UV-Si) InGaAs(IR) InGaAs Enhanced(IRE) Spectral range Si 350~1100nm Uv-Si 190~1100nm IR 800~1800nm IRE 1200~2700nm Number of blades 3 for BA3 heads 7 for BA7 heads Beam size range BA3-Si and BA3-UV 3um~5mm BA7-si and BA7-UV(Oval) 15um~10mm BA7-Si and BA7-UV(Round) 15um~9mm BA3-IR3 and BA3-IR3-E 3um~3mm BA7-IR3 and BA7-IR3-E 15um~3mm BA3-IR5 3um~5mm BA7-IR5 15um~5mm Beamwidth resolution For beams>100um in size 1um For beams<100um in size 0.1um Beamwidth accuracy ±2% Power range For Si and UV-Si heads 10uW to 1W with filters For InGaAs heads 10uW to 5mW(no filters) Power accuracy Si and Uv-Si heads ±5% InGaAs heads ±10% Power resolution 0.1uW Position resolution 1um Position accuracy ±15um Saturation Si and Uv-Si heads 0.1W/cm2 without filter 20W/cm2 with NG9 Power resolution 0.1uW Measurement rate 5Hz weight Sensor head 755gr with cable,manifold box 350gr Operating Temperature 0℃~35℃ Pc interface USB2.0(PCI optional) BeamAnalyzer USB2.0-Optional Accessories SAM3-B Beam Sampler,with mounting adapter sampling reduction factor 0.0016 average BA-Fiber A fiber adapter with an FC connecter BA-Mount A mount enabling head rotation about the optical axis Ordering Information Complete system including stand alone unit, a measuring head with 2.5m long attached cable, a mounting post, user manual on CD. NG4 and NG9 filters in housing are provided for the Si and UV-Si heads only. BA3-Si-SAT: 3-blades, Si detector 5mm circular BA7-Si-SAT: 7-blades, Si detector 9mm square BA3-UV-SAT: 3-blades, UV-Si detector 5mm circular BA7-UV-SAT: 7-blades, UV-Si detector 9mm circular BA3-IR3-SAT: 3-blades, InGaAs detector 3mm circular BA3-IR3E-SAT: 3-blades,InGaAs Enhanced 3mm circular BA7-IR3-SAT: 7-blades, InGaAs detector 3mm circular BA7-IR3E-SAT: 7-blades, InGaAs Enhanced 3mm circular BA3-IR5-SAT: 3-blades, InGaAs detector 5mm circular BA7-IR5-SAT: 7-blades, InGaAs detector 5mm circular Optional accessories SAM3-B: Beam Sampler with mounting adapter Sampling reduction factor 0.0016 average BA-Fiber: A fiber adapter with an FC connector BA-Mount: A mount enabling head rotation about the optical axis
Light Spot Analyzers